(2)折流板间距比率与圆缺率同时增大或减小,但其增大或减小幅度不同;管径、壳径、管程数增加,相同折流板间距比率所对应圆缺率减小;推荐圆缺率在之间时,折流板间距比率R取较适宜。
参考文献:
[1] 史美中,王中铮.热交换器原理与设计[M].南京:东南大学出版社,2009:53-57.
[2] HUADONG LI, VOLKER KOTTKE. Effect of baffle spacing on pressure drop and local heat transfer in shell and tube heat exchangers for staggered tube arrangement[J]. Int J Heat Mass Transfer 1998:41(10):1303-1311.
[3] Mukherjee R.Effectively design shell and tube heat exchangers.Chem Eng Progress 1998;94(2):21-37.
[4] M.Saffar-Avval, E.Damangir. A general correlation for determining optimum baffle spacing for all types of shell and tube exchangers[J]. Int J Heat Mass Transfer 1995:38(13):2501-2506.
[5] B.Khalifeh Soltan,M.Saffar-Avval. Minimizing capital and operating costs of shell and tube condensers using optimum baffle spacing[J]. Applied Thermal Engineering 24(2004) 2801-2810.
[6] Dogan Eryener.Thermoeconomic optimization of baffle spacing for shell and tube heat exchangers[J].Energy Conversion and Management 47(2006) 1478-1489.
[7] 黄文江,张剑飞.弓形折流板换热器中折流板对换热器性能的影响[J].工程热物理学报,2007,28(6):1022-1024.
[8] 喻九阳,朱兵等.折流板开孔孔径对换热器壳程性能的影响[J].石油机械,2004,32(9):9-11.
[9] 刘巍,邓方义.冷换设备工艺计算手册[M].北京:中国石化出版社,2008:23-29.
[10] 刘宏,魏新利.充分利用压降优化换热器设计[J].轻工机械,2006,24(4):158-160.
[11] 高晓东,冯霄.管壳式换热器壳程强化传热评价方法分析[J].华北电力大学学报,2007,34(2):95-97.
[12] 杨明,孟晓凤.管壳式换热器的一种优化设计[J].北京航空航天大学学报,2009,35(5):615-617.
[13] 董其伍.换热器[M].北京,化学工业出版社,2008:66-105.
[14] 谢国雄.液-液介质条件下折流板开孔对换热器传热与流阻性能的影响.武汉工程大学硕士学位论文.2006.
[15] 李汉.优化设计管壳式换热器[J].化工设计,2003,13(4):15-18.
[16] 导向科技.MATLAB6.0程序设计与实例应用.北京:中国铁道出版社,2001:147-158.
[17] 周品,何正风.MATLAB数值分析[M].北京:机械工业出版社,2009:182-184.